Medical Flowmeter

Leading Manufacturers, Exporters and Wholesaler of Five Tube Flowmeter, Flowmeter Tubes, Single Tube Flowmeter, Dual Tube Flowmeter, Dual Tube Flowmeter with AHD, Dual Tube Cascade Flowmeter, Four Tube Flowmeter, Variable Area Flowmeter, Anaesthesia Rotameters Units and Anaesthetic Rotameters Units With Anti Hypoxia from Kolkata.

Business Type Manufacturer, Exporter, Supplier
Oxygen Inlet 6 mm Festo connection from rear bottom ,(Straight)
N2o Inlet 6 Mm Festo Connection from Rear Bottom ,(straight)
Air Inlet 6 Mm Festo Connection from Rear Bottom ,(straight)
Mixed Gas Outlet 6 Mm Festo Connection from Rear ,Top,(straight)
Control Knob Oxygen Aluminium with Special Profile as per Iso 5358,
Control Knob N2O Aluminium Serrated, Serration Depth <1mm, Knob Dia Lower Than Oxygen Knob Dia
Control Knob Air Aluminium, serrated, serration depth <1mm, knob dia lower then Oxygen knob Dia.
Working pressure (max) 420 kPa (N2O, O2 &AIR)
Oxygen Tube Range Low Flow 0.1 – 1 L/min, with Graduations in Lpm Unit
Oxygen Tube Range High Flow 1 – 10 L/min, with Graduations in Lpm Unit
N2o Tube Range Low Flow 0.1 – 1 L/min, with Graduations in Lpm Unit
N2o Tube Range High Flow 1 – 12 L/min, with Graduations in Lpm Unit
Air Tube Range of Flow 0.1 – 15 L/min Graduations in Lpm Unit
Metering Tube Borosilicate Glass.
Float Aluminium-is-6063,Anodised Red –for O2, N2o & Air
Accuracy (o2, N2o & Air) As per Iso-5358
Tube Length (o2, N2o & Air) 220 Mm
Markings/identification Float Mark On Tubes & other Markings as per Iso 5358
Mounting Panel Mounting, as per Drawing
Housing Aluminum Frame, Acrylic Front, Background On White Acrylic Sheet.
Material of Construction Brass-is-319 Natural Colour/aluminium Is-6063 Anodized Natural, O Rings & Washer Epdm
Tube Fitting Arrangement Left-o2, Middle-n2o, Right –air (o2.lf-o2.hf) –(n2o.lf-n2o.hf)- (air)
Hypoxia Unit Geared Type Fitted with the Frame,
N2o Cutoff Built-in Fitted At Back
Oxygen / N2o Ratio 30 + 5% of O2 At all Settings After N2o Flow Opening.
Labels for Control Knob-o2/n2o/air O2-black On White Back Ground/n2o-white On Blue Back Ground /air-white On Black Back Ground.
Compliance To Iso-5358, Rohs
Download View
Download 01 View

Click to view more

Preferred Buyer From

Location Worldwide

Anaesthetic flowmeters are available in 2 – 5 tubes versions.  The flowmeters (2-5 tube versions) can be supplied with or without Anti Hypoxia Device.

The housings are made from Aluminum and fitted with fine adjustment valves for easy control of the anaesthetic gases. The front cover is  made from moulded acrylic. The devices have a phosphorescent “glow in the dark” (normally white) background for easy reading even in case of sudden darkness.

The knobs are made from finest quality ABS. The Oxygen knob has a touch coded profile and all the knobs are colour coded as per ISO 5358 requirements.

Internal gas connections are made using polyurethane tubes and Festo type connections. A non return valve in the downstream of the AHD ensures no flow of N2O in the respiratory circuit in the event of single fault condition when Oxygen line gets blocked.

Various options of inlet and outlet connections are available

Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Calibrated for L/min at 20 Deg C / 1013 mbar abs
Conform to ISO 5358
Bobbin Float Aluminium Alloy Anodised Red, with Silver Dot for Easily Observing Rotation

Preferred Buyer From

Location Worldwide

Optimized & Industry-ready Solutions

Flowmeter  are used for measuring  flow in Anesthesia Machine

Specification:

  • Special design float for rapid response to flow changes
  • Machine manufacturer logo printed if required
  • colour coding for each gas
  • Anti static option available
  • Other specifications can also be met.
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Inlet Nipple-6 Mm
Outlet 23mm Tapper Outlet
Control Knob Aluminium Anodized , with Special Profile as per Our Drg No.kn-016, Iso-5358
Mounting Panel
Trim Material Aluminium Anodized , Brass Nickel Plated, Front Clear & Back White Acrylic
Metering Tube Borosilicate Glass Antistatic Coated.(resistance Within < 5 M)
Float Aluminium Anodized Red
Packing Neoprene Rubber 50-60 Hs
Flow Range 0.1-10 LPM O2 (Dual range)
Operating Temp 20 Deg C
Working Pressure 4 .2 Kg/cm2g
Accuracy + 10 % of Indicated Value or 300 Ml/min Whichever is Higher (iso-5358)
Calibration Calibrated at STP (20 Deg C&1013mb abs)
Measurement As per Drg: MO-1300
Compliance Iso-5358/ Rohs

Click to view more

Preferred Buyer From

Location Worldwide

Anaesthetic flowmeters are available in single tubes versions. Available in various model.

 

Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen and Air.

  • Expended Scale Range
  • Compliant to ISO 5358, or ISO 15002, or VDI 3513 (upto G=2.5, lin=50%)
  • Color and touch coded knob as per ISO 5358
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Accuracy Compliant to ISO 5358, or ISO 15002, or VDI 3513 (upto G=2.5, lin=50%)
No. of Tubes 1-tube to 6-tubes available as standard
Tube length Borosilicate glass, Standard 230mm. Other sizes on request (See tube catalogue)
Antistatic Conductive tubes and bushes for static dissipation
Float Anodised Aluminum, Red, rotating as standard.
Anti Hypoxia 2-tube to 6-tube versions are also available with Antihypoxia device.
FA valve Available with Fine adjustment valves for accurate flow control
Gases Oxygen, Nitrous Oxide, Air, Xenon
Background Yellow green “Glow in the dark” for easy viewing
Body Anodised aluminum, or powder coated, as per your choice.
Front Front cover made from transparent acrylic sheet
Knob Color and touch coded as per ISO 5358
Download View

Click to view more

Preferred Buyer From

Location Worldwide

Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen, Nitrous oxide, Carbon dioxide, Xenon, and Air.

 

Anaesthetic Rotameters units with control valve system can be of 1 tube, 2 tubes, 3 tubes and so on as per user requirement. It comes as a complete unit for fitting on the Anaesthesia machine.

 

Flow Range

  • High flow tubes are available in ranges of 0-10, 0-12. 0-15 LPM
  • Low flow tubes are available in ranges of 0-1 LPM
  • Dual scale tubes available for expanded low range reading


Connections

  • Inlet and outlet connections are available as per your choice.
  • Most common are ISO taper with RH outlet, or 6mm Festo.
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Oxygen Inlet 6 Mm Festo Connection from Rear Bottom ,(straight)
N2o Inlet 6 Mm Festo Connection from Rear Bottom ,(straight)
Mixed Gas Outlet 6 Mm Festo Connection from Rear Top ,(straight)
Control Knob Oxygen Aluminium with Special Profile as per Iso 5358
Control Knob N2o Aluminium Serrated, Serration Depth <1mm, Knob Dia Lower Than Oxygen Knob Dia
Working Pressure (max) 420 Kpa (both N2o & O2)
Oxygen Tube Range 0.1 – 10 L/min, with Expanded Scale At 0.1 – 1 L/min Graduations in Lpm Unit
N2o Tube Range 0.1– 12 L/min, with Expanded Scale At 0.1 – 1 L/min Graduations in Lpm Unit
Metering Tube Borosilicate Glass.
Float Aluminium-is-6063,Anodised Red –for O2& N2o
Accuracy (o2& N2o) As per Iso-5358
Tube Length (o2& N2o) 220 Mm
Markings/identification Float Mark On Tubes & other Markings as per Iso 5358
Mounting Back Bar Mounting, as per Drawing
Housing Aluminum Frame, Acrylic Front, Background On White Acrylic Sheet.
Material of Construction Brass-is-319 Natural Colour/aluminium Is-6063 Anodized Natural, O Rings & Washer Epdm.
Tube Fitting Arrangement Left-n2o, Right –o2
Hypoxia Unit Geared Type Fitted with the Frame.
N2o Cutoff Built-in Fitted At Back
Oxygen / N2o Ratio 30 + 5% of O2 At all Settings After N2o Flow Opening.
Labels for Control Knob-o2/n2o O2-black On White Back Ground/n2o-white On Blue Back Ground
Compliance To Iso-5358, Rohs
Download View

Click to view more

Preferred Buyer From

Location Worldwide

Function 

The Flow Head incorporates the following Functions

  • Gas indexed pneumatic inlet ports
  • N20 gas flow cut off in the event of oxygen failure
  • Flow control needle valves
  • N20/O2 flow ratio hypoxic mixture prevention proportioning system
  • Color coded, marked specific labels for flow tubes and flow control valves
  • Gas mixing chamber, mixed gas outlet

 

 

GENERAL OPERATION

The Flow Head integrates O2 and N20.

The 02 Air and N20 needle valves gas supply pressure is externally regulated to 400Kpai10Kpa as per standard.

The N20 channel incorporates a pressure cut-oft valve. The 02 supply pressure in the circuit controls the output pressure of the pressure cut-off valve. Under all conditions of operation, the N20 flow shall reach zero before the 02 flow. In this flow head the N20 pressure switch shall cut off the flow of N20 before the 02 pressure drops below 50:15Kpa.

 

PERFORMANCE STANDARDS

Standard flow conditions defined at 20°C, 101 .3Kpa, (760mmHg) Conforms to ISO 5358 requirements.

Flow Tubes

  •  Flow Tubes are calibrated for discharge into an ambient atmosphere of 101 .3Kpa at an operating temperature of 20°C.
  • Each flow tube shall be calibrated to accuracy of 110% of reading, or better.
  • Flow tubes withstand 690Kpa internal pressure without breaking.

Flow Control Valves

  • Anti-clockwise rotation shall cause an increase inflow.
  • Flow control knob are color coded and touch coded. Smooth and precise rotation ensures accurate flow setting

 

PRESSURE CUT-OFF VALVE

  • N20 regulated pressure shall drop with falling of 02 supply pressure and shall prograssively reduce flow of this gas while
  • maintaining the proportion of 02 (22% min.) until O2 pressure falls to 50i15Kpa at which point the supply of N20 shall be cut off.
  • The only means of restoring N20 flow after 02 supply failure (O2 pressure below 50i15Kpa) shall be the restoration of 02 pressure.

ASSEMBLY

Leakage from atmosphere shall not exceed 108ml/min. when a vacuum of 80cm H20 is applied to all internal.

MATERIALS

  • All wetted material are compatible with all gases used and all anaesthetic agents.
  • Equipment compiles with HoHS requirements.
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Inlet Festo-6mm
Outlet 23 Mm Tapper Nozzle
Control Knob Aluminium with Special Profile as per Iso 5358,
Mounting Panel Mounting
Trim Material Brass-is-319 Natural Colour/aluminium Is-6063 Anodized Natural, O Rings & Washer Epdm
Metering Tube Borosilicate Glass
Metering Tube Size Low Flow-10x230, High Flow-15x230
Float Aluminium Anodized Red
Packing Epdm- 50-60 Hs
Flow Range Low Flow 0.1-1 Lpm O2 with Graduation 0.05 Lpm
Flow Range High Flow 1-10 Lpm O2 with Graduation 0.5 Lpm
Operating Temp 10-50 Deg C
Working Pressure 4 Kg/cm2g
Accuracy + 10 % of Indicated Value or 300 Ml/min Whichever is Higher (iso-5358)
Calibration Calibrated At Stp (20 Deg C&1013mb Abs)
Measurement As per Drg: M-2501-35x90x282 mm
Compliance Iso-5358/ Rohs
Download View

Click to view more

Preferred Buyer From

Location Worldwide

Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen and Air.

Anaesthetic Rotameters units with single control valve system of   2 tubes as per user requirement. It comes as a complete unit for fitting on the Anaesthesia machine for veterinary used .

  • Expended Scale Range
  • Compliant to ISO 5358, or ISO 15002, or VDI 3513 (upto G=2.5, lin=50%)
  • Color and touch coded knob as per ISO 5358
Read More...


Yes! I am interested


1, 1.2, 1.5 & 2 Nitrous Oxide Gas Max. Flow LPM
10,12,15& 20 Total Flow Below 1 L/min.
Min. 21% Total Flow Below 1 L/min. & Above
Download View

Preferred Buyer From

Location Worldwide

FUNCTION

  • The Flow Head incorporates the lollowing lunctions :
  • Gas indexed pneumatic inlet ports
  • N20 gas flow out off in the event of oxygen failure
  • Flow control needle valves
  • N20/O2 flow ratio hypoxic mixture prevention proportioning system
  • Color coded, marked specific labels for flow tubes and flow control valves
  • Gas mixing chamber, mixed gas outlet

GENERAL OPERATION

The Flow Head integrates 02 and N20 (the N20 is optional).

The O2 Air and N20 needle valves gas supply pressure is externally regulated to 400Kpa¢10Kpa as per standard.

 

The N20 channel incorporates a pressure cut-off valve. The O2 supply pressure in the circuit controls the output pressure of the pressure out-oft valve. Under all conditions of operation, the N20 flow shall reach zero before the O2 flow. ln this flow head the N20 pressure switch shall cut oft the flow of N20 before the O2 pressure drops below 50115Kpa.

 

 

Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
calibrated for L/min At 20 Deg C / 1013 Mbar Abs
Conform ISO 5358
Bobbin Float Special Design Float for Rapid Response to Flow Changes
Printing Machine Manufacturer Logo Printed if Required
Gas Coding Colour Coding for Each Gas
Anti Static Available
Download 01 View
Download 02 View
Download 03 View
Download 04 View

Click to view more

Preferred Buyer From

Location Worldwide

Flowmeter  are used for measuring  flow in Anesthesia Machine

Featurs:

  • Conforms to ISO 5358
  • Proven in meeting users‘ requirements.
  • Permanent ceramic markings fused to glass
  • Bobbin float: aluminium alloy anodised red. with
  • silver dot for easily observing rotation.
  • Special design float for rapid response to flow change
  • Machine manufacturers‘ logo prinlieci if required.
  • Colour coding for each gas.
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Type Anaesthesia Machine
Accuracy Compliant to ISO 5358, or ISO 15002, or VDI 3513 (upto G=2.5, lin=50%)
No. of Tubes 1-tube to 6-tubes available as standard
Tube length Borosilicate glass, Standard 230mm. Other sizes on request (See tube catalogue)
Antistatic Conductive tubes and bushes for static dissipation
Float Anodised Aluminum, Red, rotating as standard.
Anti Hypoxia 2-tube to 6-tube versions are also available with Antihypoxia device.
FA valve Available with Fine adjustment valves for accurate flow control
Flow Range High flow tubes are available in ranges of 0-10, 0-12. 0-15 LPM Low flow tubes are available in rang
Gases Oxygen, Nitrous Oxide, Air, Xenon
Connections Inlet and outlet connections are available as per your choice. Most common are ISO taper with RH ou
Background Yellow green “Glow in the dark” for easy viewing
Body Anodised aluminum, or powder coated, as per your choice.
Front Front cover made from transparent acrylic sheet
Description View
Download 01 View
Download 02 View

Click to view more

Preferred Buyer From

Location Worldwide

Description:

Anaesthetic Rotameters are used for measuring the rate of flow of gases used for anaesthesia. The gases measured are Oxygen, Nitrous oxide, Carbon dioxide, Xenon, and Air

Anaesthetic Rotameters units with control valve system can be of 1 tube, 2 tubes, 3 tubes and so on as per user requirement. It comes as a complete unit for fitting on the Anaesthesia machine.

 

Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Oxygen Inlet 6 mm Festo connection from rear bottom ,(Straight)
N2O Inlet 4 mm Festo connection from rear bottom ,(Straight)
Air Inlet 6 mm Festo connection from rear bottom ,(Straight)
Mixed gas outlet 10 mm Festo connection from rear ,Top right,(Straight)
Control Knob Oxygen Aluminium with special profile as per ISO 5358,
Control Knob N2O Aluminium serrated, serration depth <1mm, knob dia lower than Oxygen knob dia
Control Knob Air Aluminium, serrated, serration depth <1mm, knob dia lower then Oxygen knob Dia.
Working pressure (max) 420 kPa (N2O, O2 &AIR)
Oxygen Tube Range Low Flow 0.1  – 1 l/min, with Graduations in lpm unit
Oxygen Tube Range High Flow 1  – 10 l/min, with Graduations in lpm unit
N2O Tube Range Low Flow 0.1  – 1 l/min, with Graduations in lpm unit
N2O Tube Range High Flow 1  – 12 l/min, with Graduations in lpm unit
Air Tube Range of Flow 0.1 – 15 l/min Graduations in lpm unit
Metering Tube Borosilicate glass-antistatic coated.
Float Aluminium-IS-6063,Anodised red –for O2, N2O & AIR
Accuracy (O2, N2O & AIR) As Per ISO-5358
Tube length (O2, N2O & AIR) 230 mm
Markings/identification Float mark on tubes & other markings as per ISO 5358
Mounting Back bar mounting, as per drawing
Housing Aluminum frame with 3 side acrylic front, Luminous background on white acrylic sheet, printed as per
Material of construction Brass-IS-319 nickel plated/aluminium IS-6063 anodized black, back plate Powder coated (black), Ratio
Tube fitting arrangement Left-N2O, Middle- Air, Right –O2 (N2O.LF-N2O.HF) - (AIR)-(O2.HF-O2.LF)
Hypoxia Unit Pneumatic Type Fitted with the Frame, Diaphragm -Neoprene: Molded rubber as per Drg: DPD-004
N2O flow opening/closing Opening at 0.1-0.4 l/min Oxygen flow, while increasing Closing at 0.1-0.3 l/min Oxygen flow, while d
Oxygen / N2O ratio 30 + 10% of O2 at all settings after N2O flow opening. N2O Max Flow 12 LPM
Labels for Control Knob-O2/N2O/Air O2-Black on white back ground/N2o-white on Blue back ground /Air-white on black back ground.
Compliance to RoHS-3
Download View

Click to view more

Preferred Buyer From

Location Worldwide

Yes! I am interested



Enquiry Details
* Subject :
* Details :
Contact Information
* Your Name :
* Your Company Name :   Not Applicable
* Select Country :
* E-mail :  
* Mobile No. :
     

Looking for Product Name ?

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us